3.45.1 |
29/08/2019 |
USW3 build version: 1439
USW3 product database revision: 6109
Corrections:
- Solves an issue where the firmware could not be downloaded to the AGC 150 via TCP/IP if the PC and the controller were not on the same subnet.
- Solves an issue with wrong scaling on droop curve 2 parameters.
|
3.45.0 |
06/05/2019 |
USW3 build version: 1430
USW3 product database revision: 6024
New Features:
- Support for configurable 5 line display view in AGC 150 series.
- Support for AGC 150.
- Firmware update USB and LAN
- Bootloader update
- New Multi-Input setup page
- New Navigation icons
- Support of ASC-4 Load Point connection in Power Management applications.
Improvements:
- Commissioning view in Parameter removed when irrelevant to parameter
- Trending settings are now allowed to be down to 20 ms (0.02s) polling.
- Note: Controller may not be able to deliver data at this rate.
Corrections:
- Solves an issue where the Log page would no read all log lines.
- Solves an issue where plant read/write would fail in some occasions.
- Fixes the command line parameter for Advanced protections.
- Solves an issue introduced in USW v.3.44.0 where the "M-Logic and AOP items in use" window would not show all information.
- Solves an issue where parameters could be missing in the batch (.usw) file.
- Solves an issue introduced in USW v.3.44.0 where the AOP2 configuration could fail.
- Solves an issue where Beckhoff modules outputs were missing on the GC-1F.
- Solves an issue where the ASW is not shown when writing batch file on the AGC100.
- Fixes the battery colour in Application Supervision.
|
3.44.1 |
21/01/2019 |
USW3 build version: 1386
USW3 product database revision: 5778
Corrections
1. Advance protection Print and print preview
2. Power management now showing in M-Logic & AOP Events
3. M-Logic offline file can be opened without connecting to controller
4. Sequence CIO and PID has been changed while batch writing |
3.44.0 |
06/12/2018 |
USW3 build version: 1372
USW3 product database revision: 5733
New Features:
- M-Logic & AOP
- M-Logic and AOP configuration are now organised in tabs on the same page.
- The AOP configuration pop-up is changed to work as an AOP mimic (ASW > 4.60.0).
- Added a visual representation (diagram) of the logic blocks selected in the logic line.
- Added a toolbar for easy drag-and-drop of Events and Outputs to the logic lines.
- Dynamic M-Logic and AOP are now evaluated on the logic lines diagram.
- Parameters - Sets of Favourites
- Users can create/modify/delete sets of Favourites under the Settings page.
- Users may Import/Export Favourites sets in settings under the Settings page.
- Users can categorise parameters into different sets of Favourites.
- Favourites filter has now a drop-down menu for selecting from the available sets of Favourites.
- Parameters – Parameter management
- Users can now perform selective saving and writing of parameters.
- A new indicator help users to identify parameters that were edited, but not written.
- Users can now filtrate the parameter list for edited parameters.
- Advanced Protections configuration page for options A1, A10, C2 (ASW > 4.70.0)
- Command line
- It is now possible to merge parameter files with the command line interface.
- Merged parameters can be written to a file or written directly to a controller.
Improvements
- USW is now an available application to select from on Windows side-by-side view.
- ALCs can now be added to the left of Mains.
- Performance improvements in reading parameters (after first read).
Corrections
- Fix for batch read/write and backup/restore for PID settings and ID.
- M-Logic not displayed in USW3 under content in .usw file
|
3.43.2 |
27/09/2018 |
USW3 build version: 1236
USW3 product database revision: 5599
New
- Adds support of upcoming AGC-4 version 4.68.0.
- Adds support of upcoming AGC 200 version 4.68.0
|
3.43.2 |
12/06/2018 |
USW3 build version: 1236
USW3 product database revision: 5477
New
- Adds support to the upcoming release of ASC-4.11.0
- Adds support to the upcoming release of AGC-4.67.0
Improvements
- Changes the naming of output tab in parameters to ‘Outputs’
Fixes
- Fixes an issue in AGC 200 M-Logic where Ventilation mode and Dry mode were not working.
|
3.43.2 |
15/05/2018 |
USW3 build version: 1236
USW3 product database revision: 5368
Corrections:
- In some cases where the OS was localised, the utility software was wrongly showing a debug version message.
|
3.43.1 |
16/03/2018 |
USW3 build version: 1222
USW3 product database revision: 5368
New features:
- QR code for options upgrade
- Visual updates in application supervision
- Command buttons for DG units in supervision
- Click on unit to open its command panel
- Up to 8 configurable values may be added for each ID in supervision (only units configured on top or bottom of area)
- Sorting I/O in alphabetical order
- Duration of mouse-over texts is now configurable
- USW now stores the parameter view settings so that it opens in same view next time
- Support of AGC-4 version 4.66.0
- Support of ASC-4 battery controller
Changes:
- Various updates related to ALC-4
- Various updates related to ASC-4 PV
Corrections:
- In some situations, the USW would not show the correct application and breaker positions
- ASC Battery: When drawing a stand-alone application for ASC Battery with only the battery, the colours are wrong
|
3.42.0 |
12/10/2017 |
USW3 build version: 1164
USW3 product database revision: 5223
New features:
- Support of AGC-4 and AGC 200 version 4.65.0
- Support of new power meters on ASC-4
Corrections:
- Corrected: AGC 233 parameters not shown
- Corrected: Emulation in AGC 200 and AGC-4 not working
|
3.42.0 |
01/09/2017 |
USW3 build version: 1164
USW3 product database revision: 5181
New features:
- Radio Ripple Control Receiver (RRCR) communication support for ASC-4/ASC PM
- Option N will create exceptions for firewall, but only if the user is admin. This will be handled in the installation file
- Includes reliability data in USW files
- Dynamic evaluation added to AOP-1 and AOP-2
- Navigation in the USW even when AOP window is open
- Text representing the regulator mode
- "Save All" files function on the USW
- Support of new ID configuration
- Shows SIPC number in USW3 when USW is built/used for an SIPC
- Possible to zoom in and out in the plant view
- Support of digital I/O in trending
- Support of trend only mode
Changes:
- Inverter data support updated for ASC-4, ASC PM
- Improved dialogue when changing between units
- Application supervision unit ID on PV and LG
- CIO inputs column in the Inputs/Outputs list is made wider
- Possible to multiply the trending values so they match the CIO configuration
Corrections:
- Strange pop-up during connection to a genset group tie removed (build 1092)
- CIO added to OEM product IDs
- Unconfigured TB is no longer shown
- Corrected: Remote maintenance M-Logic missing (option H12)
- Translation no longer reveals passwords
- Option H13 added in option overview
- MB is no longer shown when opening a batch file when it is not present
- List of CIO 308 cold junction inputs is now updated when reconnecting the USW
- Unit scaling and RMI sensor type are aligned
- Russian translation of RMI corrected
- "Active alarm log" can be pulled up again after minimising
- Dialogue box no longer keeps the existing M-Logic text
- M-Logic no longer disappears during batch reading
- AGC 100: Writing phone numbers with a batch write no longer results in strange characters
- Possible to write CIO parameters with batch file
- BTBs can no longer be misplaced in application drawings with ASC/ALC
- Power management ID selection logic corrected, when using new IDs
- M-Logic event C drop-down list now always opens
- Logged alarm values are now scaled correctly
|
3.41.2 |
03/04/2017 |
USW3 build version: 1119
USW3 product database revision: 4980
New features:
- Support of AGC 222 OEM variant
|
3.41.0 |
25/11/2016 |
This software applies to the following DEIF products:
- GC-1F v.1.xx
- Multi-line 2 - AGC v.3.xx
- Multi-line 2 - PPM v.3.xx
- Multi-line 2 - PPU v.3.xx
- Multi-line 2 - GPU v.3.xx
- Multi-line 2 - GPC v.3.xx
- Multi-line 2 - AGC 200
- GC-1F ATS
- GC-1F/2 v.2.xx
- Multi-line 2 - AGC v.4.xx
- Multi-line 2 - GPU-3 REC ver. 3.xx
- Multi-line 2 - AGC 100 v. 4.xx
- Multi-line 2 - CGC 200
- Multi-line 2 - CGC 400
- Multi-line 2 - ECU 100
- Multi-line 2 - GCU 100
- Multi-line 2 - PPU v.3.xx Marine
- Multi-line 2 - GPU v.3.xx Marine
- USW3 build version: 1056
-
USW3 product database revision: 4805
Changes:
- Additional product database updated to support AGC-4 v.4.59.0.
- Alarm set point range of CIO 308 Pt100/Pt1000 inputs extended.
- Please note: Only the configuration files have changed.
New features:
- Support of CIO 116, CIO 208 and CIO 308
- Support of ALC-4 and ASC-4
Changes:
- Serial number made mandatory, in the option key generator.
- Product database updated to support AGC-4 v4.59.0
- Product database updated to support AGC 200 v4.59.0
Corrections:
- Voltmeter on device page corrected
- Buttons placed correctly in tree view
- AGC 100 "Counters and identifiers" issue corrected
- Various corrections to option N software
|
3.40.1 |
06/07/2016 |
40.1 06-07-2016
Changes:
- 1- Product database updated to support AGC-4 v4.57.0
- 2- Product database updated to support AGC 200 v4.57.0
- Please note: Only the configuration files have changed...
- 3.40.1 06-06-2016
Changes:
- Product database updated to support ASC PM Solar v5.06.0
- 3.40.1 31-05-2016
Changes:
- Product database updated to support AGC-4 v4.56.0
- Product database updated to support CGC 412 and CGC 413 v1.13.1
- Minor product database updates to AGC 252
- 3.40.1 21-12-2015 Changes:
- Added support for AGC 252
Corrections:
- PPM-3: In USW application configuration, two EDGs could be drawn, while only one EDG is supported in an application.
- Please note: Only the configuration files have changed...
3.40.1 27-11-2015
Changes:
- Updated Product Database for various products
- 3.40.1 01-07-2015 Corrections:
- USW 3.40 - F3 connection menu is not working for new users
|
3.40.0 |
24/06/2015 |
New features:
- Support of AFC PM (Automatic Fuel Controller).
- Support for Windows 8 - language selection.
- Support for 1/10000 in units.
-
Translation tree.
Changes:
- CAN line names - use of primary and secondary instead of A and B.
- Grey out of button for “activate plant configuration”, if only single unit application.
Corrections:
- Russian language causes PDF export to fail.
- Parameter texts on shared channels updated correctly.
- Missing “edit notification” in list view, after parameter change in tree view.
- Translation issues for CGC 400, AGC 100 products.
- Missing connect icon in emulation mode.
- Digital status page not updated correctly.
- TB missing in USW 3.39.0 application supervision.
- GC-1F/2 ASW 2.31.1 Application configuration should not be visible.
- AGC-3 Dual mains application configuration is not working.
- TB appearing in old application drawing when shown in newer USW version.
- Batch read from M-Logic tab not successful.
- IP address – leading zeros.
- Chinese M-Logic PDF export.
- MB present when none is configured.
- AGC 100 emulation option problem.
- Import translation from file.
|
3.39.0 |
19/09/2014 |
Re-location of USW 3.39.0 - link to NTP-patch included
3.39.0 26-09-2014 NTP patch for USW 3.39.0
A patch is needed to make the NTP-configuration work.
In future releases this won’t be necessary.
3.39.0 26-09-2014 NTP patch for USW 3.39.0
A patch is needed to make the NTP-configuration work.
In future releases this won’t be necessary.
3.39.0 26-09-2014 Re-location of USW 3.39.0 - inclusive link to NTP-patch.
New features:
- Support of ASC PM (Automatic Solar Controller).
- Support of Qc1103.
- Support for firmware download to webarm hardware with new flashes mounted.
- Support for configuration of NTP in webarm from ver. 2.40.0.
Changes:
- Possibility to change Loginfo scaling factor.
- Change of bit mask when writing inhibit configuration to device.
Corrections:
- Access level update
- CGC 400 - missing Russian letters for translation
- Russian language support now working 100%
- USW 3.38 usw files not recognised by Windows.
- PPM-3 cannot open batch files "File format error"
|
3.38.0 |
11/06/2014 |
New features:
- Update boot SW (Standard ML2 ver. 3 products)
Corrections:
- PPM-3 display of power measurement
- USW 3.37.0 freezes when connecting to PPM unit
- CGC 200: default parameters available before reading from device
- CGC 200: Parameter editor - dropdown list value selection
New features:
Update boot SW (Standard ML2 ver. 3 products)
Corrections:
PPM-3 display of power measurement
USW 3.37.0 freezes when connecting to PPM unit
CGC 200: default parameters available before reading from device
CGC 200: Parameter editor - dropdown list value selection |
|
3.37.0 |
01/04/2014 |
New features:
- Support for extended Chinese characters in CGC 400
- Support of AGC PM product
Changes:
- Scaling in Trending - Default setup and possibility to choose alternative
|
3.36.0 |
23/12/2013 |
New features:
- Parameters: Tree view for AGC 100 variants
- Parameters: Reloading of dependent parameters for AGC 100 variants
- Support of firmware upgrading over a TCP-IP connection if the AGC-4 is version 4.40, the option N has version 2.20 and the boot code has version 1.03.0
- Communication: Faster communication over TCP-IP if the option N has version 2.20
- Communication: Network parameter pop-up to easily set the IP address, netmask and gateway if the AGC-4 is version 4.40 and the option N is version 2.20
- Logs: Support of up to 500 alarms and event log lines
- Views: Tree view of the Views items
- Identifiers: Display of boot code and option N firmware version
- Identifiers: Display of production info like serial number, order number and production date
Corrections:
- Faster communication over USB when a parameter pop-up is open
|
3.35.0 |
30/08/2013 |
New features:
- Project Properties: Store user-defined comments as part of usw file
- Project Properties: Display the firmware version from which the different components inside the usw file originate
- Alarms: Double-click an alarm and open the corresponding parameter
- Parameters: Alarm status is updated while a parameter popup is open
- Parameters: Simultaneous display of multiple parameter popups
- Parameters: Export/import of the list of favorite parameters
- Parameters: Inhibits column added to the list view
- Parameters: Favorite and Modified-Parameter filters work in tree view as well (AGC-4 and AGC 200)
- Parameters: Reloading of dependent parameters (AGC-4 and AGC 200)
- Parameters: For selected parameters the Output A & B values are shown in the tree view mode (AGC-4 and AGC 200)
- Parameters: Display the parameters for the AGC 200 in a tree-like structure
- Logs: Open .sdl files originating from the flashcard in AGC 200
- New USB driver for CGC 200 and CGC 400 variants.
Corrections:
- The application retrieved during the initial connection to GCU 112 does not cause an error message
- Identifier texts with Unicode characters are not written correctly to AGC 200 products
|
3.34.1 |
08/05/2013 |
Corrections:
- The firmware flashing of the CGC 200 works on all PCs
- Scaling is working correctly for controllers configured to different power and voltage scalings
- Cos phi is removed from the Electrical data window for PPM controllers
- The apparent power (S) in the Electrical data window is correct for PPM controllers
- The offline Batch-read procedure is working correctly
- The data fields in the Electrical data no longer appear to be editable
|
3.34.0 |
20/03/2013 |
New features:
- Support of the CGC 200 and CGC 400 variants
- Support of the AGC 100 variants
- Support of the AGC 200 firmware 4.21
- Support of the ECU 100 and GCU 100 variants
- Install script updated:
a) shows EULA
b) displays the USB installation popups sequentially
c) CGC 200 USB driver added
- Supervision: Display of all available electrical data for the controllers in the application
- Supervision: Emulation support in a broad range of products (AGC 100, AGC 200 firmware >= 4.21,ECU and GCU 100 variants)
- Supervision: Save a screen copy to a graphical file
- Supervision: Plant settings popup for easy access to parameters often changed after commissioning (applies only for AGC-4 and AGC 200 variants)
- Parameters: Display of parameters in a tree-like structure (applies only for AGC-4 variants and CGC 200)
- Alarms: Acknowledge of alarms individually
- Chinese localisation
Changes:
- Connecting to device procedure is more intuitive
- Alarms: Display of current alarms and alarm history
Corrections:
- The writing of Translations has been improved
- M-Logic and AOP lines have a consistent numbering in the relevant popups
- Read logs from GC-1F no longer fail
|
3.33.0 |
09/10/2012 |
New features
- Support of redundancy (AGC-4 only)
- Indication of the parameters that have been changed since commissioning (AGC-4 only)
- Display in Appl. Supervision of the names assigned to engines, breakers and mains (AGC-4 only)
- Possibility to reset logs in the controller (AGC-4 and AGC 200 only)
Changes
- M-logic page is empty initially
- M-Logic page adjusts to the width of the window
- Device page can handle negative power values
Corrections
- Batch write issue regarding Modbus configurator data was fixed
- Application Configuration page does not show “AGC” in the header initially
- Service level user can change the access level of any parameter to any lower level
- Data tracer will show the same number of digits as in the Trending window
|
3.32.0 |
07/06/2012 |
Install script updated to remove temporary files, which can cause problems during installation
New features:
- The Connect Symbols are shown in Application Supervision to indicate the connected controller
- The texts assigned to digital inputs are shown in the Emulation inside Application Supervision
- Printout of Engine and Genset data in Application Supervision
- Applications are presented in tabs in Application Configuration
- Improved user interface to perform activation and broadcasts of applications
- Customisation of column widths in Parameter and Translations pages
- Execution of selected functions at the Windows Command prompt
- Automatic adjustment to the baud rate of the controller
- Faster batch writing of languages as those not translated are skipped
- Parameters can be tagged as favorites and a favorite filtering in the Parameter list can be applied
- The access level can be changed for a selected list of parameters
- Which columns to show and the sequence of these can be customised in the Parameters page
- Only enabled M-logic lines are shown on printouts
- Counter and Identifiers information can be printed
Changes:
- Properties of the following products were updated: AGC-3, AGC 200, PPM-3, AGC-4, GC-1F/2, PPU-3, PPM-3, GPU-3, GPC-3, GPU-3 REC, APU 264
Corrections:
- For the PPM-3 the terminal numbers given in the I/O page are correct
- Only Modbus ids in the range 1..247 are allowed
- Various improvements in the Color Scheme Editor in Supervision
- The configuration made with the Modbus Configurator can be stored as part of an usw file
- Breaker in Device page of APU 264 is updated correctly
- Older PPM-3 firmware no longer cause errors in USW 3
- Choosing the language to activate after doing translations also works with TCP-IP connection
|
3.31.0 |
|
Changes
- Product updates: AGC-3, AGC 200, PPM-3, PPU-3, GPU-3, GPC-3, GPU-3 REC, GC-1F/2, AGC-4
- OEM options are removed from the Options page.
- OEM options are removed from the Option wizard.
- The user access level required for performing an update of the controller firmware of a GC- 1F is changed to "Customer".
- The keyboard shortcut “Alt+Tab” allows navigation back and forth between the USW and other applications even when a popup is open
- Trending allows only realistic sample rates.
New features
- The Modbus Configurator (to set up the configurable memory area) is built into the USW
- Modbus configuration is included in the Batch Read/Write
- Notification sounds in case of alarms and batch operations.
- Custom logo can be used on printouts
- Broadcast progress is indicated in Application Configuration and Application Supervision (if supported by controller)
- New permission rule that prevents the user to see parameters that cannot be edited at current access level
|
3.30.1 |
07/12/2011 |
Changes:
- Supervision page is updated consistently according to active application.
- Batch read/write improved when offline.
- The correct access levels are applied for GC-1F.
- Edition of Energy counters improved.
- USW no longer claims exclusive access right to files.
|
3.30.0 |
08/11/2011 |
New features
- Support of the new controller AGC-4
- Counters: read-out of various counter values from the controller
- Identifiers: read-out of various id’s used the controller
- Dynamic M-Logic evaluation: the values for the M-Logic lines are evaluated on-the-fly
- AOP and M-Logic lines in use: provide an overview of where different event types are used in the logic lines
- Batch read: allows the read-out of logs and export to Excel file format
- Backup/restore: backup a controller for later restoring
- Translations: Prompt for selection of which language to set active after the writing of translations
- The language of the USW 3 application can be set to Russian
- Support for automatic reconnection after firmware flashing
- Display of all controller views at the same time
- A time offset used during synchronizing the time of the PC with the controller can be set
- Explicit scanning for available COM ports
- Emulation of a plant and response to e.g. inputs
- Deep dive allows to navigate between the upper and lower levels of option G7 based plants
- Permission: control which access levels can do what
- Display of the engine data retrieved over j1939 by the controller
Changes
- Only buttons and menus relevant for the offline situation are shown at startup of the USW 3
- During batch read/write the sequence of items is changed
- The help functionality has been updated with the new features listed below
- An issue regarding the sending of emails and/or SMS’s from the N-option is fixed
- In offline mode the Device page corresponding to a open file is shown
- User is prohibited to enter invalid IP address in the N-Option application
- Setting of the trending update rate is fixed
- The offline writing of view is no longer, mistakenly, reported as successful
- Logs: order of first two columns Timestamp and Text is switched so Timestamp goes first
|
3.21.0 |
15/04/2011 |
- New features
- AOP, Views and I/O Settings buttons in the top toolbar are active if connected to a device or an USW file with corresponding information is loaded.
- Support of GPU-3 REC
- Support of GC-1F ATS
- Support of AGC 222
- Support of various new parameters in PPM 3.05
- The application Modbus Configurator is added as part of the USW installation. This application is used to perform a memory mapping to the configurable memory area in the devices.
- Application Settings: Functions to clear the settings that the USW saves from session to session
- Option Wizard: Last entered customer information is displayed as default
- Project properties: Option- and hardware configuration can be copied to clipboard
- In Batch Read/Write a new shortcut, Ctrl-A, selects all items Changes
- Translations written from a Chinese PC: the issue, where the character "?" was shown in GC-1F variants is fixed.
- Terminal numbers in the Inputs/Outputs page are corrected for AGC-3.
- Application Configuration is handled before Parameters during Batch Read/Write operations.
- Cyrillic K (К) handled properly
- Removal of “Generate random data”
- Supervision: “Engine data” was renamed to “Genset data”
- Writing of the netmask (AGC2xx products) is fixed.
- M-Logic dropdowns are always repopulated when connecting to another device type
- When logs are exported to Excel also the timestamps are saved in the file
|
3.20.0 |
04/02/2011 |
New features
- Support of the new product GC-1F/2
- Support of the new products APU-3, APU 264
- Move and copy items in M-Logic
- List of existing ports is displayed in communication setting popup
- Connectivity check in Supervision (require AGC firmware 3.6 and above)
- Compatibility check in Supervision (require AGC firmware 3.6 and above)
- Engine data in Supervision (require AGC firmware 3.6 and above)
- Cyrillic display option (CYD) shown in Options
- Terminal numbers shown in Input/Outputs
- Tooltip texts for parameters
- USW files can be shared among selected products series:
- AGC 212, 213, 232, 242, 243
- AGC 245, 246
- GC-1F and GC-1F/2
- List of keyboard shortcuts is extended
- Subnet mask can be edited for AGC 200 series if supported by product (require AGC firmware 3.6 and above)
- Device flashing and clock synchronization as part of the optional batch write steps.
Changes
- Improved scaling in the Device page of PPU-3, GPU-3, GPC-3, GPC-3 Hydro
- Updated Help functionality
- Installation on Windows 7 does not require administrative rights
- More intuitive tabing order in M-Logic
- Colour scheme editor and color scheme selection joined in the same popup
- Improved scaling of meters on Device page for GC-1F
|
3.16.0 |
24/08/2010 |
New features
- Import translations from file into selectable columns in Translations.
- Assign language names to translations columns.
- Change the sequence of the language columns in Translations.
- Copy language columns to other columns in Translations.
- Full 64 bit support:
- Signed USB driver for AGC 200 for 32 and 64 bit Windows platforms (XP, Vista and 7).
- Signed USB driver for AGC-3, PPM-3, PPU-3, GPU-3, GPC-3, GPU-3 Hydro for 32 and 64 bit Windows platforms (XP, Vista and 7)
- Drag-‘n-drop of USW file onto the USW application.
- Led or button number is shown in the header of the AOP item popup.
- User confirmation when writing AOP1, AOP2 or M-Logic.
Changes
- Updated Option wizard.
- Improved support of translations in AGC 200 series.
- Improved writing of translations.
- Improved support of Applications with a ring-shaped bus-bar.
- Improved error handling during writing of translations to GC-1F.
- Support of PPM 3.04.
- Support of new parameters for PPU-3, GPC-3, GPU-3, GPU-3 Hydro.
- Updated Help functionality.
|
3.15.1 |
07/05/2010 |
Changes (USW 3.15.1)
- Writing of M-Logic, AOP1 and AOP2 configurations are password protected.
- Enabled flags are written correctly when writing parameters.
- New features (USW 3.15.0)
- Support of AGC 200 variants which includes:
- Unicode text support in Translations
- Retrieval of logs
- Firmware upgrading
- Configuration of TCP/IP network parameters
- New USB driver
- Export of reports to PDF
- Support of voltage and power scaling in PPU3, GPU 3 and GPC 3
- M-Logic/AOP improvements:
- Color symbol to indicate the Enabled state of each line
- Optional user-defined description field for each line
- IP address edited in Settings dialog box through combobox with auto completion
- Plant Option dialog box: In offline mode the Product type is selected from a list of product families
- Batch Read/Write can be cancelled
- Save Application Configuration to jpeg file
- Installation file is digitally signed
Changes (USW 3.15.0)
- Increased Parameter writing speed
- Single DB application colored correctly
- Batch jobs: The caption shows whether it is a read or write batch job
- Improved export to Excel file format (content and format)
- Improved device filtering to prohibit writing of parameters from one device type to another
- Writing of M-Logic, AOP1 and AOP2 configurations are password protected
- Number of languages written in Translations cannot exceed the max allowed by the device
- Ring connected busbar is handled consistently
|
3.15.0 |
05/05/2010 |
New features
- Support of AGC 200 variants which includes:
- Unicode text support in Translations
- Retrieval of logs
- Firmware upgrading
- Configuration of TCP/IP network parameters
- New USB driver
- Export of reports to PDF
- Support of voltage and power scaling in PPU3, GPU 3 and GPC 3
- M-Logic/AOP improvements:
- Color symbol to indicate the Enabled state of each line
- Optional user-defined description field for each line
- IP address edited in Settings dialog box through combobox with auto completion
- Plant Option dialog box: In offline mode the Product type is selected from a list of product families
- Batch Read/Write can be cancelled
- Save Application Configuration to jpeg file
- Installation file is digitally signed
Changes
- Increased Parameter writing speed
- Single DB application colored correctly
- Batch jobs: The caption shows whether it is a read or write batch job
- Improved export to Excel file format (content and format)
- Improved device filtering to prohibit writing of parameters from one device type to another
- Writing of M-Logic, AOP1 and AOP2 configurations are password protected
- Number of languages written in Translations cannot exceed the max allowed by the device
- Ring connected busbar is handled consistently
New features
- Support of AGC 200 variants which includes:
a) Unicode text support in Translations
b) Retrieval of logs
c) Firmware upgrading
d) Configuration of TCP/IP network parameters
e) New USB driver
- Export of reports to PDF
- Support of voltage and power scaling in PPU3, GPU 3 and GPC 3
- M-Logic/AOP improvements:
a) Color symbol to indicate the Enabled state of each line
b) Optional user-defined description field for each line
- IP address edited in Settings dialog box through combobox with auto completion
- Plant Option dialog box: In offline mode the Product type is selected from a list of product families
- Batch Read/Write can be cancelled
- Save Application Configuration to jpeg file
- Installation file is digitally signed
Changes
- Increased Parameter writing speed
- Single DB application colored correctly
- Batch jobs: The caption shows whether it is a read or write batch job
- Improved export to Excel file format (content and format)
- Improved device filtering to prohibit writing of parameters from one device type to another
- Writing of M-Logic, AOP1 and AOP2 configurations are password protected
- Number of languages written in Translations cannot exceed the max allowed by the device
- Ring connected busbar is handled consistently
|
|
3.14.0 |
28/12/2009 |
New features:
- Support of AGC 3.50
- Support of PPM 3.03
- Support of PPU 3.00.1 and its variants
- Support of New N-Option board (M1)
- M-Logic items collapsible/expandable
- Device ID visible on the status bar
- Connected device versus USW file compatibility check
Changes:
- Dedicated GPU Hydro device overview
- Supervision legend improved
- Colour Scheme Editor in Supervision improved
- Improvements to Translations
- Improved high alarm handling when using an older USW file
- N-option button only shown for supporting devices
|
3.13.0 |
15/10/2009 |
New features:
- Support of PPU3 and its variants.
- Search facility on the Parameters view.
- File association and distinctive icon for USW files.
- Dynamic legend on the Application Supervision view.
- Adjustable Polling delay for TCP-IP communication.
Changes:
- Performance boost in M-Logic loading.
- Parameters view improvements.
- Translations view: Extended Character dialog improved.
- Support of 20 configurable views in the AGC 3.4xx
- Plant view for the gen-set mode “Mains Power Export” improved.
|
3.12.1 |
13/07/2009 |
Changes:
- Support of AGC 3.41
-
Changes:
- Support of AGC 3.41 |
|
3.12.0 |
15/06/2009 |
New features:
- Application configuration and Supervision works with up to 256 Gen-sets as supported by the G7 option in AGC 3.40
- In Application Supervision three colors are used to indicate the state of the Gen-sets and bus-bars
- Device IDs can be changed in Application Configuration
- Support of TCP-IP Modbus communication through gateway to AGC or PPM without N-option card.
- New command line parameter BATCHWRITE, which perform a batch write operation with the project file provided by the argument of the OPENFILE parameter
Changes:
- Enhancement of translations reading: Only available translations in the device are retrieved instead of all translations.
- Printing an application configuration from the USW will no longer cause it to close.
- When some multi-inputs are configured to digital inputs, their statuses are now updated in the Inputs/Outputs view.
- Various fixes and enhancements in Trending.
- Printing of translated strings is fixed.
- The USW version is shown in the title bar
|
3.11.1 |
24/03/2009 |
New features:
- User-customizable Read/Write timeouts: The connection-settings dialog allows the end-user to adjust various read/write timeouts.
Changes:
- Support for PPM - 3.01.0.
- If a firmware upgrade fails, it is not possible to repeat this operation when the display shows “BOOT MODE, FLASH ERASED” (this applies only to USW 3.11.0).
|
3.11.0 |
18/02/2009 |
New Features
Corrections
- Improvements in “Application configuration”
- Modification of “Enable” and “High alarm” columns in the parameter list
- Minor improvements to the plant view
- Scaling of plant view instruments at high voltage values improved
- Communication status improved
- Trending improvements
|
3.10.2 |
03/10/2008 |
New features:
- Added support for installation of new firmware for the AGC/PPM N-Options.
Changes:
- Improved stability of the Modbus TCP/IP interface.
- Max tags in the N-Option feature ‘Advanced logging’ changed to 48.
|
3.10.1 |
18/07/2008 |
New features:
- Clicking on the logo at the top of the navigation bar will bring you to our homepage
- Outputs A & B are now shown as explicit texts in the parameter window and the printout
- After synchronization of the translations, untranslated and already translated texts are clearly indicated
Changes:
- The commissioning panel is now active regardless of the value of the timer
- Writing a parameter file via a “batch write” will trigger a consistency check when appropriate
Corrections:
- Status when performing a “batch read” operation updated
- Two fail class groups could appear when configuring an AOP
- Button 2 on an AOP template was not aligned correctly
- Behavior of the translations synchronization updated
- Error message when leaving the translations window removed
|
3.10.0 |
30/06/2008 |
New features:
- Plant configuration and supervision (AGC 3.30)
Changes:
- Translation: Improvements in visualization and mask handling.
- Recently used file list handling updated.
- Placement of meters in AGC Dual main configuration adjusted.
- Input/Output window handling.
Corrections:
- Trending: Gain on some values adjusted.
- Data tracer: Handling of ‘Unit names’
- Firmware download recovery mode.
|
3.00.30 |
19/03/2008 |
- Backward compatibility improved for ‘.usw’-files including languages.
|
3.00.29 |
05/03/2008 |
New features:
- Translations are now part of batch operations.
- Support of all fonts/charsets (Display unit european and cyrillic, graphical display european/cyrillic and limited european/chinese).
- Extended characters dialog redesigned.
- Font selection dialog added (graphical display only).
- Baud rate negociated with the unit (GC-1F only) up to 115200 bauds.
- Communication type shown on the status bar (serial COMx, TCP-IP IP: x.x.x.x).
- Application software/firmware file extension automatically selected according to the connected unit.
Corrections:
- Batch read/write: All AOP2s (ID 1 to 5) are readen/written instead of AOP2 ID 1 only.
- Parameters: When sending parameters stored in a project file, some parameter settings (configuration bits) could be overwritten in the unit.
- Parameters: Some items on the categories tab sheet could not be reached with mouse.
- Project file properties: Some hardware items could be duplicated.
- About window: Centered on the main monitor instead of the desktop (dual monitor systems).
|
3.00.27 |
11/10/2007 |
Correction:
- This USW release circumvents an issue present in the AGC firmware between release 3.10.2 and 3.21.0, where some parameters would not appear on the parameter list as expected.
|
3.00.26 |
20/09/2007 |
New features:
- The parameter inhibits are now shown on the parameter printout (only for parameters having inhibits defined).
- Parameter printout changed a bit (alternate colors).
- AOP1/2: Possibility to name individually leds and buttons (information saved in project file).
Changes:
- AOP1/2: Leds and buttons drawing changed slightly. M-Logic rule enabled -> white background. M-Logic rule not enabled -> hatched white background.
- Parameter filtering modified.
Corrections:
- When working on a saved parameter file (in a project file), and when editing a parameter, relays could appear as transducers.
- Faulty dependency check in I/O settings when working offline (information was based its dependencies on the device information).
-
New features:
- The parameter inhibits are now shown on the parameter printout (only for parameters having inhibits defined).
- Parameter printout changed a bit (alternate colors).
- AOP1/2: Possibility to name individually leds and buttons (information saved in project file).
Changes:
- AOP1/2: Leds and buttons drawing changed slightly. M-Logic rule enabled -> white background. M-Logic rule not enabled -> hatched white background.
- Parameter filtering modified.
Corrections:
- When working on a saved parameter file (in a project file), and when editing a parameter, relays could appear as transducers.
- Faulty dependency check in I/O settings when working offline (information was based its dependencies on the device information). |
|
3.00.25 |
13/07/2007 |
- List of the most recently used project files added.
- Writing of translations improved
- Offline configuration of the AOP-1 and -2 improved
-
1- List of the most recently used project files added.
2- Writing of translations improved
3- Offline configuration of the AOP-1 and -2 improved |
|
3.00.24 |
26/06/2007 |
- Batch upload/download officially introduced (not in preview anymore).
- Save As feature
- Possibility to print all reports in A4 or Letter
- Option upgrade order form is now in english only
- AOP 1/2 printout refined
- Possibility to choose Modbus serial or TCP-IP
- Changes in the product database
- N-Option configurator
|
3.00.21 |
30/04/2007 |
|
3.0.0.20 |
23/02/2007 |
- Support of GC-1F product.
|
3.0.0.19 |
01/02/2007 |
- Support of the latest AGC release 3.1.
- Usability of the parameter category filtering improved.
- Project file handling enhanced.
- Help file format changed.
|
3.0.0.18 |
17/10/2006 |
|