Multi-line 300 PPU 300 ver. 1.0.26.5 1.0.13.0
You’re about to download Multi-line 300 PPU 300 ver. 1.0.26.5 1.0.13.0
You have chosen to download our software.
Within a few seconds, you will receive an email containing a download link.
Having trouble using the software? Please contact support@deif.com.
Best regards,
DEIF A/S
The software is subject to copyright DEIF A/S
By following the above mentioned link and downloading the file you automatically accept DEIF A/S copyright and license agreement (EULA). The license agreement can be found on www.deif.com/software
This software applies to the following DEIF products:
You’re about to download 1.0.13.0
The main changes implemented since the last version are as follows:
Versioning changed for alignment within platform.
This software package consist of:
- Multi-line 300, PPU 300
- Bundled with DU 300 SW version 1.0.14.0
PPU 300:
New features:
- AC measurement averaging:
- It is now possible to use averaging filters (200ms and 800ms) to reduce the value fluctuations from the high performance of the measurement cards.
- The averaging filter can be applied selectively to different types of measurements.
- AC measurement averaging affects data displayed by DU 300, PICUS, trending, CustomLogic, CODESYS, and Modbus.
- AC measurement averaging does not affect protections and regulation values.
- EIM3.1 Safety shutdown function:
- EIM3.1 can now be used as a safety shutdown module.
- EIM 3.1 will be able to run the engine in stand-alone mode should it no longer be able to communicate with the main processor card (PCM).
- Hybrid controller type added.
- Support of electronic engines protocols (EIC):
- Supports the Generic J1939 protocol for reading.
- J1939 values, alarms and historical events are now available.
- New engine measurement inputs + alarms added for: Oil pressure, Oil temperature, Coolant temperature, and Coolant level.
- Flexible application drawing:
- It is now possible to customise the application drawings to provide a customisable interface.
- The design of applications with multiple ring connections is now supported.
- CODESYS version information:
- It is now possible to readout CODESYS versions in PICUS in the information tab.
- It is now possible to readout if the licence key is active or not.
- It is now possible to readout what type of license is active.
- CustomLogic IO added to Flexible Modbus
Changes:
- Update rate of live data in display and PICUS is increased.
- Changed: Possible to change time and date individually from PICUS.
- The password length can now be 1 to 32 characters.
- New default password is "0" for all users.
- Controller type can now be changed during backup restoration.
- Changed parameter menu structure for Cos Phi set point. Set point, offset and limit.
- When changing single-line diagram - cleaning up alarms related to redundant breaker.
Corrections:
- Issue fixed where breaker opened before breaker open point is reached.
- Fixed issue where hidden Modbus addresses was accessible.
- Fixed issue where NELs trip if breaker is opened.
- Fixed issue with rounding problems on decimal values on Modbus data.
- Fixed issue where changing of counters from Modbus not was saved if there was a controller power cycle shortly after.
- Fixed issue where remote and local LEDs both were turned on.
- Fixed issue with unsupported functions in CODESYS libraries.
- Fixed issue where trip output does not activate when "breaker position failure" is active.
- Fixed issues where custom parameters in CODESYS stop working after multiple downloads of CODESYS application.
- Fixed rare issue where backup file was corrupted.
- Fixed issue where custom alarms do not get units in the alarm and event logs.
- Fixed issue where GAM3.2 stand-alone mode does not work with PWM output.
- Fixed issue where regulator did not reset on external stop.
- Fixed issue where extended stop delay was skipped on external stop.
- Alarm timer expired flag data added to Modbus.
- Fixed issue where BTB was not deloaded by DG.
- Fixed issue where different controller software will run in same system.
- Fixed issue where breaker open signal could be sent because of missing inhibit info on ACM3.2.
- Fixed issue where AMC3.2 protections did not work on the Shaft generator.
DU 300:
New features:
- Custom alarm action suppression: It is now possible to enable alarm suppression for custom alarms from the display.
- Fast data interface: Faster update rate of gauges, counters, status texts, and live data views.
- Engine communication:
- J1939 alarms and historical events.
- Fieldbus, configuration, supervision and CANbus error handling.
Corrections:
- Fixed translation of texts in the View designer.
- Fixed translation of message box popup breadcrumb.
- Fixed DU300 live data subheader text cutting lower case p, g, j, q, y letters.
- Fixed DU300 showing negative ampere.
- Fixed conversion between C and F not having effect on scaling (View design).
Ver. | Date | Description |
---|---|---|
1.0.13.0 |
16/02/2021 |
Versioning changed for alignment within platform. This software package consist of:
PPU 300:New features:
Changes:
|
Ver. | Date | Description |
---|---|---|
1.0.26.5 |
07/08/2025 |
This software package consist of:
Minimum required version of PICUS: 1.0.19.0 PPU 300Changes:
|
1.0.26.3 |
31/01/2024 |
This software package consist of:
Minimum required version of PICUS: 1.0.19.0 PPU 300Changes:•Fixed issue where the controller crashed creating a backup. |
1.0.26.2 |
24/12/2023 |
This software package consist of:
Minimum required version of PICUS: 1.0.19.0 PPU 300Changes:• Updated CODESYS libraries. |
1.0.26.1 |
11/12/2023 |
This software package consist of:
Minimum required version of PICUS: 1.0.19.0 PPU 300Corrections:• Optimised CPU performance. |
1.0.26.0 |
07/12/2023 |
This software package consist of:
Minimum required version of PICUS: 1.0.19.0 PPU 300New features:• Added emergency stop alarm to the parameter list. Corrections:• Corrected an issue where it was possible to override an application output from Modbus. |
1.0.21.1 |
29/03/2023 |
This software package consist of:
Minimum required version of PICUS: 1.0.19.0 PPU 300Corrections:1 - Fixed issue where the voltage offset in reactive power load share did not react |
1.0.21.0 |
21/10/2022 |
This software package consist of:
Minimum required version of PICUS: 1.0.19.0 PPU 300New feature:1 - Added support for multiple applications with a parameter to select active application and custom plant name. (Not supported by PICUS yet.) Corrections:1 - Fixed bug where SC does not close, because sync. never finishes in emulation. |
1.0.20.0 |
20/07/2022 |
This software package consist of:
Minimum required version of PICUS: 1.0.19.0 PPU 300New feature:
Changes:
Corrections:
DU 300:New features:
|
1.0.18.0 |
23/04/2022 |
This software package consist of:
Minimum required version of PICUS: 1.0.18.0 PPU 300New feature:
Corrections:
DU 300:New features:
Corrections:
|
1.0.17.0 |
10/02/2022 |
This software package consist of:
PPU 300New Features:
Corrections:
DU 300Changes:
Corrections:
|
1.0.16.0 |
13/10/2021 |
This software package consist of:
PPU 300New Features:
Corrections:
DU 300New Features:
Changes:
Corrections:
|
1.0.15.0 |
12/07/2021 |
This software package consist of:
PPU 300New Features:
Changes:
Corrections:
DU 300Changes:
Corrections:
|
1.0.14.1 |
01/06/2021 |
This software package consist of:
PPU 300Corrections:
DU 300New features:
Changes:
Corrections:
|
1.0.14.0 |
21/05/2021 |
This software package consist of:
PPU 300:New feature:
Changes:
Correction:
DU 300New features:
Changes:
Corrections:
|
1.0.13.2 |
14/04/2021 |
This software package consist of:
PPU 300:Correction:
DU 300New features:
Changes:
Corrections:
|
1.0.13.1 |
24/02/2021 |
This software package consist of:
PPU 300:Corrections:
DU 300:New features:
Changes:
Corrections:
|
1.0.13.0 |
16/02/2021 |
Versioning changed for alignment within platform. This software package consist of:
PPU 300:New features:
Changes:
|
1.0.7.0 |
09/06/2020 |
This software package consist of:
PPU 300:New features:
Correction:
DU 300:New features:
|
1.0.5.0 |
17/12/2019 |
This software package consist of:
PPU 300New features:
Changes:
Corrections:
DU 300New features:
Changes:
Corrections:
|
1.0.4.1 |
04/03/2019 |
This software package consist of:
PPU 300Corrections:
DU 300New features:
Changes:
Corrections:
|
1.0.4.1 |
19/11/2018 |
This software package consist of:
PPU 300Corrections:
DU 300
|
1.0.4.0 |
06/07/2018 |
This software package consist of:
PPU 300New features:
DU 300
|
1.0.3.0 |
20/04/2018 |
This software package consist of:
PPU 300New features:
Changes:
Corrections:
DU 300New features:
Changes:
Corrections:
|
1.0.2.0 |
29/09/2017 |
New features:
Changes:
|
1.0.1.0 |
25/08/2017 |
This software package consist of:
|
1.0.0.3 |
12/04/2017 |
This software package consist of:
PPU 300 Corrections:
DU 300 No changes |
1.0.0.2 |
14/03/2017 |
Corrections:
|
1.0.0.0 |
21/12/2016 |
PPU 300: Initial release DU 300 ver. 1.0.5.0: New features:
Changes:
Corrections:
|