iE 350 Marine application SW (Power Management)
You’re about to download iE 350 Marine application SW (Power Management)
You have chosen to download our software.
Within a few seconds, you will receive an email containing a download link.
Having trouble using the software? Please contact support@deif.com.
Best regards,
DEIF A/S
The software is subject to copyright DEIF A/S
By following the above mentioned link and downloading the file you automatically accept DEIF A/S copyright and license agreement (EULA). The license agreement can be found on www.deif.com/software
This software applies to the following DEIF products:
You’re about to download 2.0.9.0
The main changes implemented since the last version are as follows:
2.0.9.0 based on 2.0.8.1
New features
- Three pump logic routines can now be setup to control the pumping of a substance.
- Implement ECU diagnostic to enable run coil and ECU power while the engine is stopped.
- All configuration dependent values are now possible to be used in the flexible Modbus.
Changes
- Modbus timeout increased from 10 sec to 100 sec on iE 250 and iE 350.
- Number of possible Modbus connections changed from 20 to 100 on iE2 50 and iE 350.
- Added write permission for "Priorities" when controller is in emulation.
- EIC: Volvo Penta EMS2.4: "Engine Override Control Mode" changed to "Speed control".
- EIC: Volvo Penta EMS2.4: TSC1 will not be transmitted if VP70 is used for regulation.
Corrections
- Fixed issue where changes made in the UI are not registered.
- Fixed issue where the "IO configuration" menu would show empty slots.
- Fixed issue where tree-structure menu groups can't be collapsed using touch.
- Fixed issue where configuring a modbus value to "true" made the value "255" instead of "1".
- Fixed issue where measurements from multiple ECUs are not shown in UI for e.g. configuring alarms.
- Fixed issue where display user cannot clear DM2 logs.
- Fixed issue where IE controller cannot start without an MIO module.
- Fixed issue with missing alarm icons.
- Fixed issue where user can enter parameter values outside of valid range.
- Fixed checksum and counter for VP70.
- Fixed issue where controller restarts due to heavy consumers.
- Fixed issue where removing network cable would activate system NOK, IO service error and "temperature too high" alarms.
- Fixed issue where CODESYS user management files were not included in backup/restore.
- Fixed issue where linked outputs in CODESYS was hidden in IO configuration.
- Fixed issue where "Block blackout start" input was also blocking "manual close" of breaker during blackout.
Ver. | Date | Description |
---|---|---|
2.0.9.0 |
04/05/2025 |
2.0.9.0 based on 2.0.8.1New features
Changes
Corrections
|
2.0.8.1 |
10/02/2025 |
Corrections
Changes
|
2.0.8.0 |
17/01/2025 |
2.0.8.0 based on 2.0.4.1 New features
Changes
Corrections
|
2.0.4.1 |
12/07/2024 |
Initial release of the iE 350 Marine. The iE 350 Marine, our next-generation controller product line for the maritime segment, features an award-winning design ensuring intuitive and efficient operation. The iE 350 Marine exceeds IACS UR E27 cybersecurity regulations, providing robust protection against cyber threats. Engineered for superior performance and reliability, it meets the rigorous demands of modern maritime applications. This software package is intended to serve the POWER MANAGEMENT level functionality. Minimum required version of PICUS: 1.0.22.0 New features
Corrections
|