This software applies to the following DEIF products:
You’re about to download 2.0.9.0
The main changes implemented since the last version are as follows:
2.0.9.0 based on 2.0.8.1
New features
- Three pump logic routines can now be set up to control the pumping of a substance.
- Implement ECU diagnostic to enable run coil and ECU power while the engine is stopped.
- All configuration dependent values are now possible to use in the flexible Modbus.
Changes
- Modbus timeout increased from 10 sec to 100 sec on iE 250 and iE 350.
- Number of possible Modbus connections changed from 20 to 100 on iE 250 and iE 350.
- Added write permission for "Priorities" when the controller is in emulation.
- EIC: Volvo Penta EMS2.4: "Engine Override Control Mode" changed to "Speed control".
- EIC: Volvo Penta EMS2.4: TSC1 will not be transmitted if VP70 is used for regulation.
Corrections
- Fixed issue where changes made in the UI were not registered.
- Fixed issue where the "IO configuration" menu would show empty slots.
- Fixed issue where tree-structure menu groups could not be collapsed using touch.
- Fixed issue where iE 250 failed to start up without MIO module.
- Fixed issue where configuring a Modbus value to "true", made the value "255" instead of "1".
- Fixed issue where measurements from multiple ECUs were not shown in UI for e.g. configuring alarms.
- Fixed issue where the display user could not clear DM2 logs.
- Fix issue where the iE controller could not start without MIO module.
- Fixed issue with missing alarm icons.
- Fixed issue where the user could enter parameter values outside of valid range.
- Fixed checksum and counter for VP70.
- Corrected issue where the controller restarts due to heavy consumers.
- Fixed issue where PIM2.1 DIO levels were inverted.
- Fixed issue where removing the network cable would activate system NOK, IO service error and "temperature too high" alarms.
- Fixed issue where CODESYS user management files were not included in backup/restore.
- Fixed issue where linked outputs in CODESYS were hidden in the IO configuration.
- Fixed issue where "Block blackout start" input was also blocking manual close of the breaker during blackout.
- Fixed issue where PWM was not working on MIO2.1.
Ver. | Date | Description |
---|---|---|
2.0.9.0 |
04/05/2025 |
2.0.9.0 based on 2.0.8.1New features
Changes
Corrections
|
2.0.8.1 |
10/02/2025 |
Corrections
Changes
|
2.0.8.0 |
17/01/2025 |
2.0.8.0 based on 2.0.4.1 New features
Changes
Corrections
|
2.0.4.1 |
12/07/2024 |
Initial release of the iE 250 Marine. The iE 250 Marine, our next-generation controller product line for the maritime segment, features an award-winning design ensuring intuitive and efficient operation. The iE 250 Marine exceeds IACS UR E27 cybersecurity regulations, providing robust protection against cyber threats. Engineered for superior performance and reliability, it meets the rigorous demands of modern maritime applications. This software package is intended to serve the POWER MANAGEMENT level functionality. Minimum required version of PICUS: 1.0.22.0 New features
Corrections
|