Applications
Solutions
Cases
Technologies
Pages
News
Subsegments
Multi-line 300 PPU 300 ver. 1.x.x.
You’re about to download Multi-line 300 PPU 300 ver. 1.x.x.
The software you are trying to download is obsolete. Please download the latest version from this page.This software applies to the following DEIF products:
- PPU 300 CODESYS - Paralleling & protection unit with CODESYS
- PPU 300 - Paralleling & protection unit
You’re about to download 1.0.7.0
The main changes implemented since the last version are as follows:
This software package consist of:
- Multi-line 300, PPU 300
- Bundled with DU 300 SW version 1.0.11.0
PPU 300:
New features:
- Support for the new IOM3.2 and IOM3.3 cards.
- Derate of nominal power is now possible with an analogue input.
Correction:
- Fixed an issue where PICUS supervision would update if the regulator type was changed.
- Fixed an issue where EIM3.1 relay 4 wire breaker supervision was not working.
- Fixed an issue where IOM3.4 custom texts could be mixed up if more than one card were used. This fix result in a break of backward compatibility, if custom text has been used on IOM3.4 cards.
- Fixed an issue where adding a previously used extension rack to a new system could cause the controller to restart.
- Fixed an issue where connection to an extension unit could cause the controller to restart in a system with more than two extension units.
DU 300:
New features:
- Support of IOM3.2 and IOM3.3.
Ver. | Date | Description |
---|---|---|
1.0.7.0 |
09/06/2020 |
This software package consist of:
PPU 300:New features:
Correction:
DU 300:New features:
|
1.0.5.0 |
17/12/2019 |
This software package consist of:
PPU 300New features:
Changes:
Corrections:
DU 300New features:
Changes:
Corrections:
|
1.0.4.1 |
04/03/2019 |
This software package consist of:
PPU 300Corrections:
DU 300New features:
Changes:
Corrections:
|
1.0.4.1 |
19/11/2018 |
This software package consist of:
PPU 300Corrections:
DU 300
|
1.0.4.0 |
06/07/2018 |
This software package consist of:
PPU 300New features:
DU 300
|
1.0.3.0 |
20/04/2018 |
This software package consist of:
PPU 300New features:
Changes:
Corrections:
DU 300New features:
Changes:
Corrections:
|
1.0.2.0 |
29/09/2017 |
New features:
Changes:
|
1.0.1.0 |
25/08/2017 |
This software package consist of:
PPU 300 New features: 1 - 4 directional over-current alarms have been added to BTB (ANSI 67). 2 - 2 directional over-current alarms have been added to SC and SG (ANSI 67). 3 - Support of lamp test function. 4 - Support of controller identify function. 5 - Active regulator mode will be deactivated if a new is requested. 6 - Additional information regarding alarms, breaker-, busbar- and generator status made available on Modbus. 7 - Added "Critical process error"" alarm. 8 - Last DG will trip if no other feeders are closed in the plant. Changes: 1 - "Power supply" parameter menu renamed to "Hardware". 2 - "Network" parameter group moved to "Hardware" instead of "Utility". 3 - "Reset ratio" renamed to "Hysteresis" for protection alarms. 4 - General check that "Nominal settings" cannot be configured to 0. 5 - "Fixed power factor" renamed to "Fixed CosPhi". 6 - "Analog" renamed to "Analogue". 7 - "System not OK" alarm action is changed to "Warning". 8 - New ACM 3.1 software 4.0.1.4. 9 - New PCM 3.1 software 2.0.0.2. 10 - The others are version 1.0.3.0. 11 - "Directional over-current" alarm min. and max. set points have been extended to -300 % and 300 %. 12 - Only one regulator request is accepted if more have been received. 13 - It is possible to configure action on "System not OK" alarm. Corrections: 1 - Controller types SC, SG and BTB stop synchronising if measure feedback disappears. 2 – Regulator could freeze if regulators were used in custom logic. 3 - Regulator continued to regulate after feedback failure on GB. DU 300 New features: - Implemented first part of custom stylesheets - Curves have been added to parameters - Lamp test - Identify feature to communication screen - Units change on display Changes: - Navigation and editing in I/O input text is now possible from the keyboard - Default live data views updated - Edit line design has been updated - Updated counter screen to use states - Default text in keyboard will show resolution - Live data screens dynamic update (step 1) - REST version control improvement step 1 (A+B match) - REST version control improvement step 2 (new REST resource implementation) - Live data dial meter and vertical bar widgets improved - Production screen changed to versions screen, production data now visible in about screen - Added DNS possibility to communication screen - Added IPv6 address to communication screen - Live data using REST to build screen and widgets - Terminal values updated to only show allowed precision - Updated help screens Corrections: - Custom inhibit does no longer clear other inhibit flags - Placeholder text from previous screen does no longer influence logon screen - Handling of empty list in pair screen - Pair screen automatically keeps rescanning for controllers if previously connected to a controller - Elements in parameters are represented in the same order as in the base unit - Preparation of lists in the application improved - Removed dot key from keyboard when value is integer, or precision is zero - Network off pop-up did not show the first time the display lost connection - Do not allow user to press OK in empty pair list - Cardlist serial to be a string instead of integer - Display reboots after setting up AVR - No longer showing all functions when function groups is empty - Cleaned up warnings - Not able to enable/disable the alarm "Ethernet redundancy broken" |
1.0.0.3 |
12/04/2017 |
This software package consist of:
PPU 300
Corrections: DU 300 No changes |
1.0.0.2 |
14/03/2017 |
Corrections:
|
1.0.0.0 |
21/12/2016 |
PPU 300: Initial release DU 300 ver. 1.0.5.0: New features:
Changes:
Corrections:
|
On this page, you can download software updates for your product(s) and help yourself to various utility tools and add-ons that will assist you in setting up, detecting faults and configuring your product(s).
Please be advised that not all of our products can be updated by the user. Nor do all of our products come with a utility tool. Consequently, the list on this page cannot be considered an overview of our product programme.
DEIF will register your download along with the used e-mail address for the purpose of sending out information on future updates, if requested.
DEIF cannot be made responsible for any consequences of failed product updates or use of utility tools. Nor can DEIF A/S be made responsible for consequences of changes in behaviour of products due to a software upgrade. It is always the responsibility of the user to ensure correct set-up and configuration before commissioning. Please study the version log of the software before updating the product.
Licence agreement for software downloaded from www.deif.com
Downloaded software remains the property of DEIF. The software may not be distributed for commercial purposes, changed or reused in full or in part or sold to any third parties.
The latest versions for full functionality
As always, we recommend that you install our offered improvements to fully utilise your DEIF product.
All improved software can be downloaded at your convenience at www.deif.com under “Software”.
Should you have any questions or experience problems finding the relevant software for your product, please feel free to call DEIF A/S at +45 96149614 or your relevant local DEIF office. Alternatively, we are always ready to assist you, if you send an e-mail to support@deif.com.
Press release, June 2015